IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. CAUTION To prevent electrical shock, do not mate unit connector until installation is complete and A.C.
power is supplied to the unit.
2. CAUTION This fixture provides more than one power supply output source. To reduce the risk of electrical
shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by discon
-
necting the unit connector.
3. CAUTION This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace
the entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly.
4. DO NOT USE OUTDOORS. The I-13-EM-B is for use with grounded, UL Listed, damp location rated, indoor
fixtures. Not for use in heated air outlets or hazardous locations.
5. The I-13-EM-B requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the unused
A.C. lead.
6. When the installation is complete, switch the A.C. power on and join the I-13-EM-B unit connector.
7. Do not mount near gas or electric heaters.
8. The I-13-EM-B should be mounted in locations and at heights where it will not readily be subjected to tamper
-
ing by unauthorized personnel.
9. The I-13-EM-B will cold strike and operate one 5W, 7W, or 9W, twin tube, double twin tube, 180ma or 13W
twin tube, double twin tube, 285ma fluorescent lamp, each with a single lampholder per lamp.
10. The I-13-EM-B is for use with fluorescent downlight fixtures.
11. Suitable for use in damp locations and in enclosed and gasketed fixtures.
12. When used in conjunction with enclosed and gasketed fixtures, the I-13-EM-B is suitable for mounting in the
ballast compartment only.
13. For use in 0° C minimum, 50° C maximum ambient temperatures.
14. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition, void
warranty, and result in non-compliance with UL specifications.
15. Do not use this equipment for other than intended use.
16. When the installation is complete, switch the A.C. power on and join the I-13-EM-B unit connector..
Install in accordance with the National Electrical Code and local regulations.
17. Installation and servicing should be performed by qualified personnel.
18. Lighting fixture manufacturers, electricians and end users need to ensure product system compatibility before
final installation.
SAVE THESE INSTRUCTIONS
I-13-EM-B
INSTRUCTION MANUAL
SERIES D
COMPACT LAMP
EMERGENCY
LIGHTING EQUIPMENT
P.O. BOX 11846 TUCSON, AZ 85734
(520) 294-3292 FAX (520) 741-2837
www.iotaengineering.com
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - I-13-EM-B

IMPORTANT SAFEGUARDSWhen using electrical equipment, basic safety precautions should always be followed, including the following:READ AND FOLLOW ALL S

Page 2 - INSTALLATION INSTRUCTIONS

Page 2INSTALLATION INSTRUCTIONSCAUTION: Before installing, make certain the A.C. power is off and the I-13-EM-B unit connector is disconnected.1.

Page 3 - TESTING & MAINTENANCE

Page 35. LABELS Attach the appropriate labels adjacent to the Test Switch and Charge Indicator. Annotate Re-lamping label for lamp type and wattage

Page 4 - TYPICAL WIRING DIAGRAMS

Page 4UNITCONNECTORCHARGEINDICATORTESTSWITCHRED ORRED/BLK (+)WHT/BLKBLK (120V)ORG (277V)WHITEBLUE/WHTBLUEYELLOWYEL/BLKBLUEBLACKUNSWITCHED LINECOMMONSW

Page 5

Page 56. TWO LAMP PARALLEL HIGH POWER FACTOR MAGNETIC BALLAST8. TWO LAMP SERIES HIGH POWER FACTOR MAGNETIC BALLASTUNITCONNECTORCHARGEINDICATORRED ORRE

Comments to this Manuals

No comments